Differences
This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
sensors:galvanic_skin_response [2021/03/24 15:32] charles.reimer [Applications & Uses] |
sensors:galvanic_skin_response [2021/03/24 15:39] (current) charles.reimer [Available Sensors & Specifications] |
||
---|---|---|---|
Line 142: | Line 142: | ||
The use of EDA measures and other biosensors can allow for non-invasive measurement of individuals of cognitive and affective states while not interrupting the performance of other tasks. This can allow for the development of affective computing systems that dynamically respond to users’ cognitive and affective state in real time. In many cases, feature extraction alone may be all that is required from EDA data; however, machine learning algorithms are useful when considering systems that need to adapt and respond to changing EDA measurements in real-time. | The use of EDA measures and other biosensors can allow for non-invasive measurement of individuals of cognitive and affective states while not interrupting the performance of other tasks. This can allow for the development of affective computing systems that dynamically respond to users’ cognitive and affective state in real time. In many cases, feature extraction alone may be all that is required from EDA data; however, machine learning algorithms are useful when considering systems that need to adapt and respond to changing EDA measurements in real-time. | ||
- | One notable affective computing application is [[https:// | + | One notable affective computing application is [[https:// |
EDA sensors have been used in number of musical applications. One notable example is [[https:// | EDA sensors have been used in number of musical applications. One notable example is [[https:// | ||
Line 163: | Line 163: | ||
|company=BioPac | |company=BioPac | ||
|model=SS57LA | |model=SS57LA | ||
- | |sources=[[https:// | + | |sources=[[https:// |
|description=EDA Electrode Leads | |description=EDA Electrode Leads | ||
|datasheet=None | |datasheet=None | ||
Line 174: | Line 174: | ||
|company=Biosignalsplux | |company=Biosignalsplux | ||
|model=Electrodermal Activity (EDA) | |model=Electrodermal Activity (EDA) | ||
- | |sources=[[https:// | + | |sources=[[https:// |
|description=EDA Electrode Leads | |description=EDA Electrode Leads | ||
|datasheet=[[https:// | |datasheet=[[https:// | ||
Line 185: | Line 185: | ||
|company=BITalino | |company=BITalino | ||
|model=EDA Sensor | |model=EDA Sensor | ||
- | |sources=[[https:// | + | |sources=[[https:// |
|description=Arduino-compatible EDA sensor | |description=Arduino-compatible EDA sensor | ||
|datasheet=[[https:// | |datasheet=[[https:// | ||
Line 196: | Line 196: | ||
|company=Empatica | |company=Empatica | ||
|model=E4 | |model=E4 | ||
- | |sources=[[https:// | + | |sources=[[https:// |
|description=Wearable bracelet with sensors for EDA and other physiological phenomena | |description=Wearable bracelet with sensors for EDA and other physiological phenomena | ||
|datasheet=[[https:// | |datasheet=[[https:// | ||
Line 207: | Line 207: | ||
|company=Infusion Systems | |company=Infusion Systems | ||
|model=BioEmo | |model=BioEmo | ||
- | |sources=[[https:// | + | |sources=[[https:// |
|description=GSR impedance sensor | |description=GSR impedance sensor | ||
|datasheet=Technical Specifications can be found at [[https:// | |datasheet=Technical Specifications can be found at [[https:// | ||
Line 218: | Line 218: | ||
|company=Mindfield Biosystems | |company=Mindfield Biosystems | ||
|model=eSense Skin Response | |model=eSense Skin Response | ||
- | |sources=[[https:// | + | |sources=[[https:// |
|description=Skin conductance sensor which can send data through phone/ | |description=Skin conductance sensor which can send data through phone/ | ||
|datasheet=See [[https:// | |datasheet=See [[https:// | ||
Line 229: | Line 229: | ||
|company=Movisens | |company=Movisens | ||
|model=EdaMove 4 | |model=EdaMove 4 | ||
- | |sources=[[https:// | + | |sources=[[https:// |
|description=Bluetooth sensor for collecting various physiological data | |description=Bluetooth sensor for collecting various physiological data | ||
|datasheet=[[https:// | |datasheet=[[https:// | ||
Line 240: | Line 240: | ||
|company=Seeed Studio | |company=Seeed Studio | ||
|model=GSR Sensor | |model=GSR Sensor | ||
- | |sources=[[https:// | + | |sources=[[https:// |
|description=Arduino-/ | |description=Arduino-/ | ||
|datasheet=Brief technical specifications are available at [[https:// | |datasheet=Brief technical specifications are available at [[https:// | ||
Line 251: | Line 251: | ||
|company=Shimmer Sensing | |company=Shimmer Sensing | ||
|model=Shimmer3 EDA+ | |model=Shimmer3 EDA+ | ||
- | |sources=[[https:// | + | |sources=[[https:// |
|description=Wireless GSR and pulse-sensing system | |description=Wireless GSR and pulse-sensing system | ||
|datasheet=[[https:// | |datasheet=[[https:// |